Publication Information (EuropePMC) | |
Title | Genetic analysis in European ancestry individuals identifies 517 loci associated with liver enzymes. |
PubMed ID | 33972514(Europe PMC) |
doi | 10.1038/s41467-021-22338-2 |
Publication Date | May 10, 2021 |
Journal | Nat Commun |
Author(s) | Pazoki R, Vujkovic M, Elliott J, Evangelou E, Gill D, Ghanbari M, van der Most PJ, Pinto RC, Wielscher M, Farlik M, Zuber V, de Knegt RJ, Snieder H, Uitterlinden AG, Lifelines Cohort Study, Lynch JA, Jiang X, Said S, Kaplan DE, Lee KM, Serper M, Carr RM, Tsao PS, Atkinson SR, Dehghan A, Tzoulaki I, Ikram MA, Herzig KH, Järvelin MR, Alizadeh BZ, O'Donnell CJ, Saleheen D, Voight BF, Chang KM, Thursz MR, Elliott P, VA Million Veteran Program. |
Polygenic Score ID & Name | PGS Publication ID (PGP) | Reported Trait | Mapped Trait(s) (Ontology) | Number of Variants |
Ancestry distribution GWAS Dev Eval |
Scoring File (FTP Link) |
---|---|---|---|---|---|---|
PGS000817 (GRS200_GGT) |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Gamma-glutamyl transferase | serum gamma-glutamyl transferase measurement | 200 | https://ftp.ebi.ac.uk/pub/databases/spot/pgs/scores/PGS000817/ScoringFiles/PGS000817.txt.gz | |
PGS000816 (GRS150_ALT) |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Alanine transaminase | serum alanine aminotransferase measurement | 150 | https://ftp.ebi.ac.uk/pub/databases/spot/pgs/scores/PGS000816/ScoringFiles/PGS000816.txt.gz | |
PGS000815 (GRS290_ALP) |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Alkaline phosphatase | alkaline phosphatase measurement | 290 | https://ftp.ebi.ac.uk/pub/databases/spot/pgs/scores/PGS000815/ScoringFiles/PGS000815.txt.gz |
PGS Performance Metric ID (PPM) |
Evaluated Score |
PGS Sample Set ID (PSS) |
Performance Source | Trait |
PGS Effect Sizes (per SD change) |
Classification Metrics | Other Metrics | Covariates Included in the Model |
PGS Performance: Other Relevant Information |
---|---|---|---|---|---|---|---|---|---|
PPM002176 | PGS000816 (GRS150_ALT) |
PSS001062| European Ancestry| 3,620 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum alanine transaminase level | OR: 1.72 [1.36, 2.07] | — | — | — | — |
PPM002177 | PGS000817 (GRS200_GGT) |
PSS001062| European Ancestry| 3,620 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum gamma-glutamyl transferase level | OR: 1.96 [1.72, 2.19] | — | — | — | — |
PPM002172 | PGS000815 (GRS290_ALP) |
PSS001060| European Ancestry| 331 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum alkaline phosphatase level | β: 2.07 [1.49, 2.66] | — | — | — | Unit of measurement = U/L in alkaline phosphatase |
PPM002173 | PGS000816 (GRS150_ALT) |
PSS001060| European Ancestry| 331 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum alanine transaminase level | β: 3.09 [2.02, 4.17] | — | — | — | Unit of measurement = U/L in alanine transaminase |
PPM002174 | PGS000817 (GRS200_GGT) |
PSS001061| European Ancestry| 13,420 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum gamma-glutamyl transferase level | β: 1.43 [1.35, 1.52] | — | — | — | Unit of measurement = U/L in gamma-glutamyl transferase |
PPM002175 | PGS000815 (GRS290_ALP) |
PSS001062| European Ancestry| 3,620 individuals |
PGP000201 | Pazoki R et al. Nat Commun (2021) |
Reported Trait: Serum alkaline phosphatase level | OR: 1.88 [1.67, 2.09] | — | — | — | — |
PGS Sample Set ID (PSS) |
Phenotype Definitions and Methods | Participant Follow-up Time | Sample Numbers | Age of Study Participants | Sample Ancestry | Additional Ancestry Description | Cohort(s) | Additional Sample/Cohort Information |
---|---|---|---|---|---|---|---|---|
PSS001060 | Serum concentrations of alanine transaminase (ALT) and alkaline phosphatase (ALP), were measured from stored blood samples using the enzymatic rate analytical method on a Beckman Coulter AU5800. The manufacturer’s analytic range for ALT was 3–500 U/L, for ALP, 5–1500 U/L, and it was 5–1200 U/L for GGT. | — | 331 individuals | — | European | — | Airwave | — |
PSS001061 | The serum concentration of gamma-glutamyl transferase (GGT) was measured from stored blood samples using the enzymatic rate analytical method on a Beckman Coulter AU5800. The manufacturer’s analytic range for ALT was 3–500 U/L, for ALP, 5–1500 U/L, and it was 5–1200 U/L for GGT. | — | 13,420 individuals | — | European | — | Airwave | — |
PSS001062 | Serum concentrations of alanine transaminase (ALT), alkaline phosphatase (ALP), and gamma-glutamyl transferase (GGT) were measured from stored blood samples using the enzymatic rate analytical method on a Beckman Coulter AU5800. The manufacturer’s analytic range for ALT was 3–500 U/L, for ALP, 5–1500 U/L, and it was 5–1200 U/L for GGT. | — | 3,620 individuals | — | European | — | NFBC | — |